The Beko 12 Climatizzatore is a 12000 BTU air conditioner designed for efficient cooling and dehumidification of medium-sized rooms. It features multiple operating modes (Cool, Dry, Fan, Auto), a 24-hour programmable timer, adjustable fan speeds, a sleep function for quiet nighttime operation, remote control, washable air filters, and an auto-swing louvre for even air distribution. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Modes 7. Timer and Special Functions 8. Maintenance & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Indoor unit with display and controls, Remote Control, Outdoor unit, Power cord, Drain hose, Window mounting kit.

FeatureDescription
Cooling Capacity12000 BTU/h for rooms up to 25 m²
Operating ModesCool, Dry, Fan, Auto
Fan SpeedsLow, Medium, High, Auto
Timer24-hour programmable On/Off timer
Sleep ModeQuiet operation with gradual temperature adjustment
Air SwingAuto vertical/horizontal louvre movement
FilterWashable anti-bacterial air filter
Remote ControlFull function remote with battery
Power Supply220-240V AC, 50Hz
Energy ClassA++ for high efficiency

Installation

Unpack and inspect all components. Choose a suitable window or wall location.

  1. Install mounting bracket: Secure bracket to wall or window sill using provided screws.
  2. Place indoor unit: Carefully lift unit onto bracket ensuring it is level and secure.
  3. Connect outdoor unit: Attach refrigerant lines and electrical connections following color codes.
  4. Install drain hose: Route hose to proper drainage point with downward slope.
  5. Seal openings: Use foam strips to seal gaps around window installation.
  6. Plug into dedicated power outlet.

WARNING! Installation should be performed by qualified personnel. Ensure proper support for heavy units.

First-Time Setup

After installation, perform initial setup before first use.

  1. Power on: Plug in unit and press POWER button on remote or unit.
  2. Select mode: Use MODE button to choose Cool, Dry, Fan, or Auto.
  3. Set temperature: Use TEMP buttons to set desired temperature (16°C-30°C).
  4. Adjust fan speed: Select Low, Medium, High, or Auto fan speed.
  5. Test functions: Verify timer, sleep mode, and air swing operation.

CAUTION! Allow unit to sit upright for 2 hours after transport before first use.

Specifications

Controls and Settings

Control via front panel buttons or remote control. Front Panel: POWER, MODE, TEMP up/down, FAN SPEED, TIMER.

Remote: POWER, MODE, TEMP ▲/▼, FAN SPEED, TIMER, SLEEP, SWING, TURBO, LED display.

Temperature Setting: Range 16°C-30°C in 1°C increments. Fan Speed: Low (quiet), Medium (balanced), High (rapid cooling), Auto (automatic adjustment). Mode Selection: Cool (standard cooling), Dry (dehumidification), Fan (air circulation only), Auto (automatic mode selection based on room temperature).

Operating Modes

Cool Mode: For standard air conditioning. Set desired temperature; unit cools until reached. Dry Mode: Reduces humidity without significant cooling. Ideal for humid days. Fan Mode: Circulates air without cooling or dehumidifying. Auto Mode: Unit automatically selects Cool, Dry, or Fan based on room conditions.

  1. Press MODE to cycle through available modes.
  2. For Cool/Dry modes, set temperature with TEMP buttons.
  3. Select fan speed appropriate for current needs.
  4. Use SWING button to activate auto air distribution.

Tip: Use Dry mode when humidity is high but temperature is moderate.

Timer and Special Functions

Timer: Program unit to turn On/Off at specific times.

  1. Press TIMER button on remote.
  2. Use ▲/▼ to set hours (0-24).
  3. Press TIMER again to confirm.
  4. LED displays timer icon when active.

Sleep Mode: Optimizes comfort during sleep.

  1. Press SLEEP button.
  2. Temperature gradually increases by 1°C per hour (up to 3°C).
  3. Fan operates at lowest speed for quiet operation.
  4. Sleep mode automatically turns off after 8 hours.

Turbo Mode: Press TURBO for maximum cooling power for 30 minutes.

WARNING! Do not run unit continuously at maximum settings for extended periods.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Unplug unit before any maintenance.
  2. Clean air filter every 2 weeks: Remove filter, wash with mild soap and water, dry completely before reinstalling.
  3. Clean exterior: Wipe with soft, damp cloth. Do not use abrasive cleaners.
  4. Clean condenser coils annually: Use soft brush to remove dust.
  5. Check drain hose: Ensure it is not blocked and drains properly.

CAUTION! Never use water to clean internal components. Do not operate without air filter installed.

Regulatory Information

CE certified: Complies with European safety and EMC directives. RoHS compliant: Free of hazardous substances. Disposal: Follow local regulations for disposal of electrical equipment. For support, visit www.beko.com or contact customer service at +39 800 525 016.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower supplyCheck power cord connection; ensure outlet has power; check circuit breaker.
Poor cooling performanceDirty filters/settingsClean air filter; ensure temperature setting is correct; check for obstructions.
Water leakageBlocked drainCheck drain hose for blockages; ensure proper slope for drainage.
Unusual noisesLoose parts/obstructionsCheck for loose panels; remove obstructions near fan; ensure unit is level.
Remote not workingBatteries/distanceReplace batteries; ensure direct line of sight to unit's sensor; remove obstacles.
Error codes displayedSystem faultsNote error code; consult manual; power cycle unit; contact service if persistent.

Reset: Unplug unit for 5 minutes, then restart to reset control system.

Service: +39 800 525 016; www.beko.com

climatizzatore 12 beko manuale © - All Rights Reserved 2025